Extreme Environment Test Data
Defense & Extreme Distribution Environment Certification
The following performance data is representative of polymer fusion label performance using ASTM D7932-14 and MIL-STD 810G for labeling to be used in extreme distribution environments. All tests referenced are shown below.
PERFORMANCE DATA
The following performance data is representative of polymer fusion label performance using
| TEST NAME | TEST SPEC / REQUIREMENT | SURFACE | RESULT |
|---|---|---|---|
| High Temperature | |||
| High Temperature | 95–120°F for 24hrs for 7 Days | HDPE, PP Test Plaques | Exceeded performance criteria |
| Low Temperature | |||
| Low Temperature | -60°F for 72hrs | HDPE, PP Test Plaques | Exceeded performance criteria |
| Rainfall | |||
| Rainfall | 40MPH raindrops for 40min | HDPE, PP Test Plaques | Exceeded performance criteria |
| Salt Fog, Salt Spray | |||
| Salt Fog, Salt Spray | 5% salt solution at 95°F | HDPE, PP Test Plaques | Exceeded performance criteria |
| Blowing Dust | |||
| Blowing Dust | Blown dust @ 2mph for 6hrs | HDPE, PP Test Plaques | Exceeded performance criteria |
| Humidity | |||
| Humidity | 80°F, 95–100% humidity 45 days | HDPE, PP Test Plaques | Exceeded performance criteria |
| Freeze / Thaw, Temperature Cycling | |||
| Temperature Cycling | 3 cycles 77°F, 95% RH to 18°F | HDPE, PP Test Plaques | Exceeded performance criteria |
| Accelerated Aging, Thermal Testing | |||
| Aging, Thermal | 150°F, 80% humidity, 96hrs | HDPE, PP Test Plaques | Exceeded performance criteria |
| Solar Radiation, Xenon Exposure | |||
| Solar, Xenon | (56) 24 hour cycles | HDPE, PP Test Plaques | Exceeded performance criteria |
| Abrasion Resistance, Desert | |||
| Abrasion, Desert | 500g @ 60rpm at 60°C ± 2 | HDPE, PP Test Plaques | Exceeded performance criteria |
| Abrasion Resistance, Room Temperature | |||
| Abrasion, Room Temp. | 500g @ 60rpm at room temp. | HDPE, PP Test Plaques | Exceeded performance criteria |
| Abrasion Resistance, Cryogenic | |||
| Abrasion, Cryogenic | 500g @ 60rpm at -55°C ± 3 | HDPE, PP Test Plaques | Exceeded performance criteria |
| Chemical Resistance Testing | |||
| Deionized Water | 8hr. exposure, max 24hr dry | HDPE, PP Test Plaques | Exceeded performance criteria |
| 5% Salt Water | 8hr. exposure, max 24hr dry | HDPE, PP Test Plaques | Exceeded performance criteria |
| Windex | 8hr. exposure, max 24hr dry | HDPE, PP Test Plaques | Exceeded performance criteria |
| Betco AF67 Bathroom Cleaner | 8hr. exposure, max 24hr dry | HDPE, PP Test Plaques | Exceeded performance criteria |
| 99% Isopropyl Alcohol | 8hr. exposure, max 24hr dry | HDPE, PP Test Plaques | Exceeded performance criteria |
| Dot 3 Brake Fluid | 8hr. exposure, max 24hr dry | HDPE, PP Test Plaques | Exceeded performance criteria |
| #2 Diesel Fuel | 8hr. exposure, max 24hr dry | HDPE, PP Test Plaques | Exceeded performance criteria |
| Nitric Acid - Ph 1.0±0.2 | 8hr. exposure, max 24hr dry | HDPE, PP Test Plaques | Exceeded performance criteria |
| HCL - Ph 1.0 ± 0.2 | 8hr. exposure, max 24hr dry | HDPE, PP Test Plaques | Exceeded performance criteria |
| Sodium Hydroxide - Ph 12±0.2 @ 5.25% | 8hr. exposure, max 24hr dry | HDPE, PP Test Plaques | Exceeded performance criteria |
| Sodium Hypochlorite - 5% | 8hr. exposure, max 24hr dry | HDPE, PP Test Plaques | Exceeded performance criteria |
| Quaternary Ammonium 200 ppm | 8hr. exposure, max 24hr dry | HDPE, PP Test Plaques | Exceeded performance criteria |
| FDA 510(k) Durability Requirement | |||
| 600 Wash Cycles | 250ppm ZEP FSZ-Chlor (#2443) | HDPE, PP Test Plaques | Exceeded performance criteria |
High Temperature
TEST NAME
High Temperature
TEST SPEC / REQUIREMENT
95–120°F for 24hrs for 7 Days
SURFACE
HDPE, PP Test Plaques
RESULT
Exceeded performance criteria
Low Temperature
TEST NAME
Low Temperature
TEST SPEC / REQUIREMENT
-60°F for 72hrs
SURFACE
HDPE, PP Test Plaques
RESULT
Exceeded performance criteria
Rainfall
TEST NAME
Rainfall
TEST SPEC / REQUIREMENT
40MPH raindrops for 40min
SURFACE
HDPE, PP Test Plaques
RESULT
Exceeded performance criteria
Salt Fog, Salt Spray
TEST NAME
Salt Fog, Salt Spray
TEST SPEC / REQUIREMENT
5% salt solution at 95°F
SURFACE
HDPE, PP Test Plaques
RESULT
Exceeded performance criteria
Blowing Dust
TEST NAME
Blowing Dust
TEST SPEC / REQUIREMENT
Blown dust @ 2mph for 6hrs
SURFACE
HDPE, PP Test Plaques
RESULT
Exceeded performance criteria
Humidity
TEST NAME
Humidity
TEST SPEC / REQUIREMENT
80°F, 95–100% humidity 45 days
SURFACE
HDPE, PP Test Plaques
RESULT
Exceeded performance criteria
Freeze / Thaw, Temperature Cycling
TEST NAME
Temperature Cycling
TEST SPEC / REQUIREMENT
3 cycles 77°F, 95% RH to 18°F
SURFACE
HDPE, PP Test Plaques
RESULT
Exceeded performance criteria
Accelerated Aging, Thermal Testing
TEST NAME
Aging, Thermal
TEST SPEC / REQUIREMENT
150°F, 80% humidity, 96hrs
SURFACE
HDPE, PP Test Plaques
RESULT
Exceeded performance criteria
Solar Radiation, Xenon Exposure
TEST NAME
Solar, Xenon
TEST SPEC / REQUIREMENT
(56) 24 hour cycles
SURFACE
HDPE, PP Test Plaques
RESULT
Exceeded performance criteria
Abrasion Resistance, Desert
TEST NAME
Abrasion, Desert
TEST SPEC / REQUIREMENT
500g @ 60rpm at 60°C ± 2
SURFACE
HDPE, PP Test Plaques
RESULT
Exceeded performance criteria
Abrasion Resistance, Room Temperature
TEST NAME
Abrasion, Room Temp.
TEST SPEC / REQUIREMENT
500g @ 60rpm at room temp.
SURFACE
HDPE, PP Test Plaques
RESULT
Exceeded performance criteria
Abrasion Resistance, Cryogenic
TEST NAME
Abrasion, Cryogenic
TEST SPEC / REQUIREMENT
500g @ 60rpm at -55°C ± 3
SURFACE
HDPE, PP Test Plaques
RESULT
Exceeded performance criteria
Chemical Resistance Testing
TEST NAME
Deionized Water
TEST SPEC / REQUIREMENT
8hr. exposure, max 24hr dry
SURFACE
HDPE, PP Test Plaques
RESULT
Exceeded performance criteria
TEST NAME
5% Salt Water
TEST SPEC / REQUIREMENT
8hr. exposure, max 24hr dry
SURFACE
HDPE, PP Test Plaques
RESULT
Exceeded performance criteria
TEST NAME
Windex
TEST SPEC / REQUIREMENT
8hr. exposure, max 24hr dry
SURFACE
HDPE, PP Test Plaques
RESULT
Exceeded performance criteria
TEST NAME
Betco AF67 Bathroom Cleaner
TEST SPEC / REQUIREMENT
8hr. exposure, max 24hr dry
SURFACE
HDPE, PP Test Plaques
RESULT
Exceeded performance criteria
TEST NAME
99% Isopropyl Alcohol
TEST SPEC / REQUIREMENT
8hr. exposure, max 24hr dry
SURFACE
HDPE, PP Test Plaques
RESULT
Exceeded performance criteria
TEST NAME
Dot 3 Brake Fluid
TEST SPEC / REQUIREMENT
8hr. exposure, max 24hr dry
SURFACE
HDPE, PP Test Plaques
RESULT
Exceeded performance criteria
TEST NAME
#2 Diesel Fuel
TEST SPEC / REQUIREMENT
8hr. exposure, max 24hr dry
SURFACE
HDPE, PP Test Plaques
RESULT
Exceeded performance criteria
TEST NAME
Nitric Acid - Ph 1.0±0.2
TEST SPEC / REQUIREMENT
8hr. exposure, max 24hr dry
SURFACE
HDPE, PP Test Plaques
RESULT
Exceeded performance criteria
TEST NAME
HCL - Ph 1.0 ± 0.2
TEST SPEC / REQUIREMENT
8hr. exposure, max 24hr dry
SURFACE
HDPE, PP Test Plaques
RESULT
Exceeded performance criteria
TEST NAME
Sodium Hydroxide - Ph 12±0.2 @ 5.25%
TEST SPEC / REQUIREMENT
8hr. exposure, max 24hr dry
SURFACE
HDPE, PP Test Plaques
RESULT
Exceeded performance criteria
TEST NAME
Sodium Hypochlorite - 5%
TEST SPEC / REQUIREMENT
8hr. exposure, max 24hr dry
SURFACE
HDPE, PP Test Plaques
RESULT
Exceeded performance criteria
TEST NAME
Quaternary Ammonium 200 ppm
TEST SPEC / REQUIREMENT
8hr. exposure, max 24hr dry
SURFACE
HDPE, PP Test Plaques
RESULT
Exceeded performance criteria
FDA 510(k) Durability Requirement
TEST NAME
600 Wash Cycles
TEST SPEC / REQUIREMENT
250ppm ZEP FSZ-Chlor (#2443)
SURFACE
HDPE, PP Test Plaques
RESULT
Exceeded performance criteria